Title of article
Methods for measuring diffusion coefficients of radon in building materials
Author/Authors
I. Cozmuta ، نويسنده , , E.R. van der Graaf، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
13
From page
323
To page
335
Abstract
Two methods for determining the Rn-222 diffusion coefficient in concrete are presented. Experimentally, the flush
and adsorption technique to measure radon release rates underlines both methods. Theoretically, the first method
was developed for samples of cubical geometry. The radon diffusion equation was solved for boundary conditions
imposing zero flux conditions successively on each side. In practice, a 100% effective covering would ensure this
condition to be satisfied. The diffusion coefficient is then determined by comparing the computed and respectively
measured normalized ratios of the radon release rates with respect to the rate corresponding to the open-boundaries
Žuncovered. specimen. As in practice, none of the investigated coverings showed to be effective in reducing radon
exhalation, indicating that radon-tight sealing of surfaces is far from trivial, no clear conclusions could be drawn with
respect to the diffusion coefficient. The second method can be applied to specimens that are first reshaped into
hollow cylinders. A one-dimensional situation can be inforced by requiring that the flux vanishes at the two ends of
the hollow cylinder. The theoretical and experimental ratios are again compared. In practice, the radon flux
originates from a radon source enclosed inside the hollow cylinder, the effectiveness of the sealing being previously
tested on an aluminum dummy of similar dimensions. The radon bulk diffusion coefficient for the used concrete
sample resulted in a value of D Ž4.6 0.4. 10 6 cm2 s 1.
Keywords
RADON , Concrete , Measurement method , Release rate , Diffusion coefficient
Journal title
Science of the Total Environment
Serial Year
2001
Journal title
Science of the Total Environment
Record number
982631