Title of article :
Estimation of minimum power consumption and
pumps cost for the differential pumping system
Author/Authors :
Y. Itou، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The air-to-air vacuum sealing device is composed of evacuated multi stages and the differential pumping system to maintain
the pressure of the deposition chamber at 5 10ÿ2 Pa. The differential pumping system is adopted to evacuate the deposition
chamber with minimum power consumption and pumps cost through the estimation of air ¯ow rate and pressure. The air ¯ow
rate of each stage (Q) and pressure (P) is calculated accurately in region of viscos ¯ow, viscos slip ¯ow, transient ¯ow,
molecular ¯ow based on the experimental results. # 2001 Elsevier Science B.V. All rights reserved.
Keywords :
power consumption , pressure , Air-to-air vacuum sealing device
Journal title :
Applied Surface Science
Journal title :
Applied Surface Science