Title of article
Steady-state surface concentration profiles of primary ion species during secondary ion mass spectrometry measurements
Author/Authors
S. Yoshikawa، نويسنده , , H. Morita، نويسنده , , F. Toujou، نويسنده , , T. Matsunaga ، نويسنده , , T. K. Tsukamoto ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
4
From page
252
To page
255
Abstract
The steady-state surface concentration profiles of Cs ions during secondary ion mass spectrometry (SIMS) measurements were investigated in details for Si using low-energy oxygen primary ion bombardment. Depending on the bombardment conditions of Cs primary ions, there are shoulder regions or transient regions under the sputtered surface where Si secondary ion intensities are lower than those at bulk region. To achieve accurate depth profiling with minimum transient region using Cs primary ions, it is necessary to choose bombardment conditions such that primary ion energy is below 1 keV or large angle of incidence over 80° will be needed for higher primary ion energy.
Keywords
Transient region , SIMS , Depth profiling , Bombardment conditions , Steady State
Journal title
Applied Surface Science
Serial Year
2003
Journal title
Applied Surface Science
Record number
998432