• Title of article

    Steady-state surface concentration profiles of primary ion species during secondary ion mass spectrometry measurements

  • Author/Authors

    S. Yoshikawa، نويسنده , , H. Morita، نويسنده , , F. Toujou، نويسنده , , T. Matsunaga ، نويسنده , , T. K. Tsukamoto ، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    4
  • From page
    252
  • To page
    255
  • Abstract
    The steady-state surface concentration profiles of Cs ions during secondary ion mass spectrometry (SIMS) measurements were investigated in details for Si using low-energy oxygen primary ion bombardment. Depending on the bombardment conditions of Cs primary ions, there are shoulder regions or transient regions under the sputtered surface where Si secondary ion intensities are lower than those at bulk region. To achieve accurate depth profiling with minimum transient region using Cs primary ions, it is necessary to choose bombardment conditions such that primary ion energy is below 1 keV or large angle of incidence over 80° will be needed for higher primary ion energy.
  • Keywords
    Transient region , SIMS , Depth profiling , Bombardment conditions , Steady State
  • Journal title
    Applied Surface Science
  • Serial Year
    2003
  • Journal title
    Applied Surface Science
  • Record number

    998432