Title of article :
Gas poisoning investigations of scandate and M-type dispenser cathodes
Author/Authors :
Wensheng Shao، نويسنده , , Ke Zhang، نويسنده , , Ji Li، نويسنده , , Suqiu Yan، نويسنده , , Qilue Chen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
54
To page :
58
Abstract :
Gas poisoning tests of cathode emission were carried out with four kinds of thermal cathodes: W+Sc2O3 mixed matrix cathode, impregnated scandate cathode, Ir-coated cathode, Os-coated cathode. As a result, M-type cathodes are more sensitive to O2, but can recover absolutely in a short time; scandate-type cathodes react slowly and recover partly after a long time. Compared to O2, ambient air leaked into the vacuum chamber has a smaller influence on the cathode emission; H2 has a little effect of activation on the four cathodes, especially on the Os-coated cathode.
Keywords :
M-cathode , Scandate cathode , Ir-coated cathode , Os-coated cathode , Gas poisoning
Journal title :
Applied Surface Science
Serial Year :
2003
Journal title :
Applied Surface Science
Record number :
998560
Link To Document :
بازگشت