چكيده لاتين :
The technique of in-situ electrodeposition, coupled with ETAAS (ED-ETAAS), has been
developed for determination of ultra-traces of manganese and vanadium in environmental
samples. The goal is electrodeposition of ultra-traces of analyte onto the renewable Pd-coated
substrate at optimized conditions of voltage, time of deposition and pH of sample solution prior
to measurement by ETAAS. The characteristic masses in the determination of manganese and
vanadium are superior to those of conventional ETAAS (Conv-ETAAS) measurements. The
detection limits for the interested elements have been improved over those of Conv-ETAAS,
with precision of the determinations in the range of 1-3 RSD%. In this work, a technique was
developed for speciation of these elements in the environmental samples. Therefore, a solid
phase extraction method, coupled with ETAAS or ED-ETAAS, has been investigated for this
purpose. The results showed that it could be a fast and sensitive method for manganese and
vanadium speciation. A C18 cartridge, modified with sodium diethyldithiocarbamate (SDDTC),
has been employed for the selective separation of manganese (VII) ions from other associated
metal ions, especially manganese (II), even at much higher concentrations, followed by EDETAAS
determination. To separate vanadium (IV) from vanadium (V), a modified membrane
disk loaded with disodium ethylenediaminetetraacetic acid (Na2EDTA) was used to trap both
vanadium species, then, the vanadium (IV) ion was eluted selectively and ED-ETAAS was used
for determination.