Textile industry is the major source of water consumption and wastewater pollution. There are various treatment techniques to remove textile wastewater pollution. Coagulation-flocculation is a widely used process to remove pollution due to suspended particles. In this research,
different coagulants like Alum, Lime, FeCI3, FeS04 and MgCl2 were applied to select the suitable ones with optimum removal efficiency of sulfuric dyes. Settling characteristics of floes formed in the coagulation process were studied in a laboratory scale settling column unit. Parameters such as color, COD, TSS, turbidity and settled sludge volume have been evaluated. The optimum coagulant dose and pH value were determined by comparing the effectiveness of these coagulants. Results showed other coagulants except lime could eliminate color and COD. In this case, FeSO4 was chosen as an optimum coagulant for color removal because of the lowest required coagulant dose, minimum
settled sludge volume and maximum de-colorization.