شماره ركورد
70655
عنوان مقاله
Study the otoacoustic emissions at different stimulus levels
پديد آورندگان
Al-Maamury, Adnan Mohsin Ali AL-Mustansiriya university - college of science - Department of physics, Iraq
از صفحه
208
تا صفحه
228
تعداد صفحه
21
چكيده عربي
لا يمكن إدراج ملخص المقال
چكيده لاتين
In this study the otoacoustic emission has been studied for three persons with vary stimulus 60,65,and 70 dB pSPL, in this study the TEOAE latency will be evaluated as a function of the stimulus level, to get information on the dependence of cochlear tuning on the stimulus level and to compare the results with the predictions of transmission line cochlear-models. show the latency for many frequencies and the different between the cases and in the same time compare the result. The cochlear latency has been evaluated in young adults by timefrequency analysis of transient evoked otoacoustic emissions recorded using the nonlinear acquisition mode at different levels of the click stimulus. The frequency is a function of the latency so in this wok we calculated the latencies for three persons by using matching pursuit method and we found that the latency is a function of stimulus level.
كليدواژه
otoacoustic emissions , different stimulus levels
سال انتشار
2011
عنوان نشريه
مجله كليه التربيه
عنوان نشريه
مجله كليه التربيه
لينک به اين مدرک