شماره ركورد كنفرانس
4014
عنوان مقاله
Using 2-[(thiophene-2-yl-methylene)-amino]-isoindole-1,3-dione as a new selector element to develop the potentiometric iron (III) - selective electrode
پديدآورندگان
Joz-Yarmohammadi Fatemeh fatemeh.yarmohamadi@gmail.com Islamic Azad University , Zamani Hassan Ali fatemeh.yarmohamadi@gmail.com Islamic Azad University
تعداد صفحه
3
كليدواژه
PVC Membrane , Potentiometric Sensor , Ion Selective Electrode , Iron (III)
سال انتشار
1395
عنوان كنفرانس
دوازدهمين سمينار سالانه الكتروشيمي ايران
زبان مدرك
انگليسي
چكيده فارسي
A new Fe3+ ions selective electrode based on 2-[(thiophene-2-yl-methylene)-amino]-isoindole-
1,3-dione was prepared to apply as an indicator electrode in the potentiometric cell. The best
electrode response was observed in the slope (20.1±0.9 mV per decade) over a wide neodymium
ion concentration range of 1.0×10-6 to 1.0×10-2 M with a detection limit of 8.5×10−7M.