عنوان مقاله :
Electrochemical study of doxorubicin on the surface of SBA-15 modified screen -printed carbon electrode
پديدآورندگان :
Edalatkar Akram University of Mazandaran , Raoof Jahan Bakhsh j.raoof@umz.ac.ir University of Mazandaran , Bagheri Hashkavayi Ayemeh University of Mazandaran , Ojani Reza University of Mazandaran
كليدواژه :
SPE , Doxorubicin , mesoporous silica SBA , 15 , electrochemical impedance spectroscopy.
عنوان كنفرانس :
دوازدهمين سمينار سالانه الكتروشيمي ايران
چكيده فارسي :
Doxorubicin (DOX), has been nearly recognized as the ‘‘gold standard’’ for the treatment of
various cancers including solid breast, ovarian, lung and liver tumors. However, the side effects
such as systemic toxicity, cardiotoxicity and drug resistance gradually appear during the therapy.
Therefore, there is an emergent need for rapid, easy and sensitive techniques for analysis of DOX
.The performance of sensors can be significantly improved by using different nanomaterials. One
of these materials is mesoporous silica SBA-15. SBA-15 is a promising candidate for the
immobilization of various materials and can be used to create stable biosensing. Sensors based on
the SBA-15 have shown high sensitivity and good detection limit through promoting electron
transfer reaction and enhancing electrochemical signal. In this project, a simple and novel sensor is
developed for study of clinical DOX concentration based on SBA-15 on the surface of SPE .The
SBA-15 modified screen printed electrode (SPE) was fabricated to monitor the DOX in phosphate
buffer solution (pH 6.0). A droplet of 9μL SBA-15 was placed on the working electrode surface,
followed by air-drying for 1.0 h. The interaction of SBA-15 on the working electrode surface with
DOX was investigated in the drug solution. The electrochemical behavior of DOX was observed at
the surface of SBA-15-modified SPE by cyclic voltammetry (CV) and electrochemical impedance
spectroscopy. The effect of pH and scan rate on the reduction current of DOX was studied using
cyclic voltammetry. From the obtained results, pH 6.0 was obtained as the optimum pH. Also scan
rate showed that the reduction peak current increased with increasing in scan rate from 10 to 400
mV s-1. From the calculated results, the electron transfer coefficient was obtained 0.49. Under
optimized condition, the measured reduction peak current of DOX by differential pulse
voltammetry exhibited a good linear relationship with the increasing of the DOX concentration in
the range of 0.002 μM to 2μM. The detection limit was founded to be5.4×10-6μM.