  • چكيده فارسي
    A simple, rapid, precise and accurate isocratic reversed-phase HPLC method was developed and validated for determination of Betahistine Hydrochloride in commercial tablets. Separation was achieved on a Phenomenax C18 column (150 mm × 4.6 mm, 5 µm) using a mobile phase consisting of acetonitrile-sodium acetate buffer (pH 4.7) (35:65, v/v) at a flow rate of 1.5 ml min-1 and UV detection at 254 nm. The column temperature was maintained at 40 ºC. The linearity of the proposed method was investigated in the range of 0.256-0.384 mg mL-1 (r = 0.9984). Precision were less than 2.0% and accuracy was between 99.81% and 100.88%. This method was validated and successfully applied in analysis of tablet dosage form because no chromatographic interferences from formulation excipients were found.
  • چكيده لاتين
    A simple, rapid, precise and accurate isocratic reversed-phase HPLC method was developed and validated for determination of Betahistine Hydrochloride in commercial tablets. Separation was achieved on a Phenomenax C18 column (150 mm × 4.6 mm, 5 µm) using a mobile phase consisting of acetonitrile-sodium acetate buffer (pH 4.7) (35:65, v/v) at a flow rate of 1.5 ml min-1 and UV detection at 254 nm. The column temperature was maintained at 40 ºC. The linearity of the proposed method was investigated in the range of 0.256-0.384 mg mL-1 (r = 0.9984). Precision were less than 2.0% and accuracy was between 99.81% and 100.88%. This method was validated and successfully applied in analysis of tablet dosage form because no chromatographic interferences from formulation excipients were found.