شماره ركورد كنفرانس :
4567
عنوان مقاله :
Aluminum Hydroxide-based Flame Retardant Composite Separator for Lithium-ion Batteries
Author/Authors :
A Nahvi Bayani Institute of Mechanics - Iranian Space Research Center, Shiraz, Iran , M. H Moghim Institute of Mechanics - Iranian Space Research Center, Shiraz, Iran , S Bahadorikhalili Institute of Mechanics - Iranian Space Research Center, Shiraz, Iran , A. M Ghasemi Institute of Mechanics - Iranian Space Research Center, Shiraz, Iran
كليدواژه :
Li-ion Battery separator , Flame Retardancy , Aluminum Hydroxide
عنوان كنفرانس :
ششمين كنفرانس ملي ساليانه انرژي پاك
چكيده لاتين :
Despite the extensive use of polyolefins, especially as the lithium-ion battery (LIB)
separators, their flammability limits them for large-scale battery applications.
Therefore, fabrication of flame retardant LIB separators has attracted lots of
attention in recent years. In this work, composite separators were prepared by
applying a ceramic-based coating layer comprising a metal hydroxide as a filler
and flame retardant agent (Al(OH)3) and a P(VDF-HFP) binder to the
polypropylene (PP) commercial separator. Thermal shrinkage, thickness, air
permeability, porosity and flammability of fabricated ceramic-coated composite
separator were investigated. The results showed that the addition of Al(OH)3
particles improved thermal shrinkage (~8%) and flame retardancy of commercial
separator which can prevent dimensional changes at high temperatures and
significantly increase LIBs safety. Applied 11μm ceramic-based coating layer on
PP commercial separator had 76% porosity which increased the value of air
permeability from 278.15 (sec 100 ml-1) to 312.8 (sec 100 ml-1) suggests much
facile air permeation through the pores of commercial separator than the composite
one. Furthermore, suitable electrolyte wettability of ceramic coated separator
(135%) facilitates ion transport through the pores. All these characteristics make
the fabricated flame retardant Al(OH)3 composite separator an appropriate
candidate to ensure the safety of large-scale LIB.