شماره ركورد كنفرانس :
5060
عنوان مقاله :
The Assessment of PI and Optimized OCC Control Methods in Buck Converter
Author/Authors :
،Mohammad Shahabi Department of Electrical Engineering K.N.Toosi University Of Technology Tehran, Iran , ، Ahmadreza Alavi Koosha Department of Electrical Engineering K.N.Toosi University Of Technology Tehran, Iran , ، Karim Abbaszadeh Department of Electrical Engineering K.N.Toosi University Of Technology Tehran, Iran
كليدواژه :
DC-DC converters , buck converter , PI control method , dynamic behavior , optimized One Cycle control method , instrument controls , simulation results, practical implementation
عنوان كنفرانس :
11th Power Electronics, Drive Systems, and Technologies Conference (PEDSTC)
چكيده فارسي :
فاقد چكيده فارسي
چكيده لاتين :
In Power Electronics sciences, DC-DC converters
have a special place. The buck converter, which is a kind of
them that decreases high-level voltage, is being used in many
applications that need voltage level changes. One of the vital
challenges is how to control converters with the highest working
efficiency and the lowest cost, considering the dynamic behavior
of the converter. In the last papers, various control methods were
provided to control the converters and each had its advantages
and disadvantages. The PI is one of the traditional control
methods that had been used because of its comfortable analogue
implementation and relatively good performance in eliminating
systems error. The One Cycle Control (OCC) method is one of
the newer control methods that has been much more successful in
controlling the converters. One of the most critical features of this
controller is detecting changes and perturbations of input voltage
only during one switching period and rejecting them and also
immediately following the reference voltage. In this research, in
addition to the diode voltage, a feedback loop is also taken from
the output voltage which is known as improved OCC method
but the most advantages of presented method is the simplicity of
structure and, consequently, reducing the cost of construction. So
it can be called as optimized OCC. Due to the excellent dynamic
behavior of the OCC control method, it is used as a controller in
many sensitive industries such as instrument controls, navigation
systems and so on. The primary purpose of this paper is to
compare PI and optimized OCC methods applying to a buck
converter. The simulation results in Simulink/MATLAB show the
high speed of system response and the high sensitivity of the
optimized OCC method indicate changes in buck converter. The
practical implementation results, also has verified the simulation
results.