كليدواژه :
precast moment resisting frame , precast dual system , semi rigid connection , reduction factor , push over analysis
چكيده لاتين :
Reduction factor is an important factor in linear analysis that indicates inelastic operations of structures
such as resistance and ductility in nonlinear stage. In seismic codes, this coefficient is just written with a
constant value. Despite of many researches on this factor in monolithic constructions, complete research
on this field in precast structures has not already been done. This is one of the reasons that make the
necessity of research in this case indispensable. In this paper, different types of precast concrete moment
resisting frames in 4, 6, and 8 stories, that each storey has 3 meters height, with 3 bays in length of 5
meters, accompany them 3 different popular connections related to beam to column precast connection,
horizontal panel joint and vertical panel joint in precast industry, are studied. Nonlinear static analysis
(pushover) in triangular form has been used in this study. Besides Perform 3D software is used for
modeling and analysis. Results indicate while precast concrete moment frames with semi rigid
connections have smaller Reduction factor than monolithic moment frames, precast dual systems could
have equal or more values than equivalent monolithic dual systems