شماره ركورد كنفرانس :
4891
عنوان مقاله :
Effect of Interface Condition on Lining Structural Performance in Tunnels Support
Author/Authors :
Ansari Meysam Engineering Department - Power and Water University of Technology , Safi Mohammad Power and Water University of Technology
كليدواژه :
Interface condition , Tangential spring , Frictional performance , lining Performance Wall friction
سال انتشار :
1391
عنوان كنفرانس :
نهمين كنگره بين المللي مهندسي عمران
زبان مدرك :
انگليسي
چكيده فارسي :
فاقد چكيده فارسي
چكيده لاتين :
With respect to the frictional performance of the 3D panels studied in this research, the tunnel wall friction plays an important role in distribution of internal forces and consequently optimum design of tunnel support system, hence, the main objective in this study is achieving the appropriate range of the wall friction and based on this range, determining the most accommodating soil type. In this article the tunnel cross section has been assumed as a reinforced concrete, and also it is assumed that the soil cohesion has no effect on the analysis.In the both static and dynamic condition, for different values oftangential spring stiffnesses, analysis of the tunnel structure,using SAP 2000 software, was carried out and by means of interaction diagram, optimal range of wall friction ascertained. As a consequence this study, in the static analysis more wall friction prefers whereas having less wall friction, in the dynamic analysis, is better
كشور :
ايران
تعداد صفحه 2 :
8
از صفحه :
1
تا صفحه :
8
لينک به اين مدرک :