Prediction of Mean drop Size in Pulsed Packed Extraction Columns
Author/Authors :
Meisam ،Torab-Mostaedi , Jaber ،Safdari , Farzad ،Torabi-Hokmabadi School of Chemical Engineering - University College of Engineering - University of Tehran - Tehran, Iran
كليدواژه :
Pulsed Packed Column , Sauter Mean Diameter , drop Size , Holdup
عنوان كنفرانس :
ششمين كنگره بين المللي مهندسي شيمي
چكيده لاتين :
In the present work, Sauter mean drop sizes have been measured in a pulsed packed extraction column for two liquid
systems. The effects of pulsation intensity, phase flow rates, and interfacial tension on drop size have been investigated
under a variety of operating conditions. The drop size is influenced mainly by pulsation intensity and interfacial tension.
Significant, but weaker, are the effects of continuous and dispersed phase flow rates. A precise correlation is proposed
for predicting mean drop size in terms of operating variables and physical properties of the liquid systems. Good
agreement between prediction and experiments is found for all operating conditions that were investigated.