پديدآورندگان :
Rashidi Mohadeseh mohadesehrashidii1378@gmail.com Department of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, Tehran, Iran , Harivandi Mahdi m.harivandi7@gmail.com School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran , Mehrjoo Mohammad mohamadmehrjoo@yahoo.com School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran , Malekan Mehdi mmalekan@ut.ac.ir School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran , Mojtahedi Milad m.mojtahedi@razi.ac.ir Department of Materials and Textile Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran
كليدواژه :
HEA , FeCoNiCuMn , heat treatment , corrosion resistance , potentiodynamic , polarization test
چكيده فارسي :
Vacuum furnace cast FeCoNiCuMn high-entropy alloy was annealed at four conditions: the temperatures of 850°C and 1000°C for 2 and 12 hours. The effect of heat treatment on microstructure was investigated using optical and scanning electron microscopy. The corrosion resistance of the samples was also studied using linear polarization method. The results of Tofel extrapolation revealed that annealing at 850°C reduced the icorr, while the maximum studied temperature and time of heating made the corrosion resistance worse than the as-cast sample. All samples exhibited satisfactory corrosion resistance in a 3.5% NaCl solution