Author/Authors :
Luis A. Aguirre and Marcus F. S. Pereira، نويسنده ,
DocumentNumber :
1384243
Title Of Article :
A modified observer scheme for fault detection and isolation applied to a poorly observed process with integration
شماره ركورد :
11100
Latin Abstract :
This paper investigates the application of the dedicated observer scheme (DOS) to a real tank system. As described, this system is not ʹDOS-instrument-fault-detectableʹ due to the location of the sensors and the dynamical characteristics of the system itself. In order to overcome such a difficulty, this work proposes a dedicated observer scheme with periodic resetting (DOSPR). The design of the observers and the new algorithm are detailed in the paper. The new procedure was tuned and tested on a pilot plant. A complete nonlinear model with physical parameters measured from the plant are included. Some results are discussed in the paper.
From Page :
47
NaturalLanguageKeyword :
fault detection and isolation , Observers , monitoring systems
JournalTitle :
Studia Iranica
To Page :
56
To Page :
56
Link To Document :
بازگشت