• Author/Authors

    Talay, S Erzurum Eğitim ve Araştırma Hastanesi - Kalp Damar Cerrahisi Kliniği, Turkey , Kaygın, M A Erzurum Eğitim ve Araştırma Hastanesi - Kalp Damar Cerrahisi Kliniği, Turkey , Dağ, Ö Erzurum Eğitim ve Araştırma Hastanesi - Kalp Damar Cerrahisi Kliniği, Turkey , Erkut, B Erzurum Eğitim ve Araştırma Hastanesi - Kalp Damar Cerrahisi Kliniği, Turkey

  • Title Of Article

    Aneurysm of membranous septum as a long-term complication of mechanical aortic valve replacement

  • شماره ركورد
    14750
  • Abstract
    We report a case of an unusual morphological complication of a mechanical aortic valve replacement which was observed as an aneurysm formation from the interventricular membranous septum during the first postoperative year. The aneurysm resulted in a functional impairment of the mechanical prosthesis with elevated pressure gradients and valve leak. However, due to the severe neurological status of the patient’s emergent administration, an aneurysmectomy and/or renewal of aortic valve prosthesis was not possible. We hereby present the clinical and echocardiographical evaluation of the case.
  • From Page
    267
  • NaturalLanguageKeyword
    Mechanical aortic valve replacement , late postoperative complication , aneurysm of inter , ventricular membranous septum , cardiac surgery , valve disease
  • JournalTitle
    Ege Journal Of Medicine
  • To Page
    268
  • JournalTitle
    Ege Journal Of Medicine