DocumentCode :
1000037
Title :
A precision transformer used for an audio-frequency power standard
Author :
Zhang, Deshi ; Jia, Yaolan
Author_Institution :
Nat. Inst. of Metrol., Beijing, China
Volume :
39
Issue :
3
fYear :
1990
fDate :
6/1/1990 12:00:00 AM
Firstpage :
547
Lastpage :
549
Abstract :
A precision current transformer for the audio-frequency band in which an auxiliary current transformer equalizes the potential along the primary and secondary windings of the main current transformer is discussed. The arrangement results in a dramatic reduction of capacitive leakage current. In this way, a ratio error of less than 10 p.p.m. and phase angle error of less than 10 μrad is achieved at frequencies up to 10000 Hz
Keywords :
current transformers; leakage currents; measurement errors; measurement standards; power measurement; 10000 Hz; audio-frequency power standard; capacitive leakage current; current transformer; phase angle error; precision transformer; primary windings; secondary windings; Capacitance; Current transformers; Frequency conversion; Impedance; Leakage current; Magnetic cores; Metrology; Standards development; Thermal stability; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.106291
Filename :
106291
Link To Document :
بازگشت