Title :
Pilot-plant testing of a novel electrostatic collector for submicrometer particles
Author :
Bologa, Andrei M. ; Paur, Hanns-Rudolf ; Seifert, Helmut ; Wäscher, Thomas
Author_Institution :
Inst. fur Tech. Chem., Forschungszentrum Karlsruhe GmbH, Germany
Abstract :
A novel electrostatic collector CAROLA (Corona Aerosol Abscheider) for gas cleaning from submicrometer particles is described. The CAROLA concept is based on particle charging by corona discharge and subsequent particle removal in the grounded part of the collector. CAROLA collectors for fine oil mists and for fly ash were tested. The influence of the operation conditions on corona discharge was studied. It is shown that the CAROLA electrostatic collectors have high fractional removal efficiencies (>98% for particles >1 μm and 95%-98% for particles with sizes 0.3-1 μm), low operating voltages (10-20 kV), and low pressure drop (<200 Pa). The collection of charged particles without external electric field and the compact design provide a cost-effective solution for the removal of submicrometer particles from industrial off gases.
Keywords :
aerosols; air pollution control; corona; electrostatic devices; electrostatic discharge; fly ash; 10 to 20 kV; corona aerosol abscheider; corona discharge; electric field; electrostatic collector; electrostatic collectors; fly ash; particle charging; particle removal; pilot-plant testing; submicrometer particles; Aerosols; Cleaning; Corona; Electrostatics; Fly ash; Gas industry; Low voltage; Particle charging; Petroleum; Testing; Corona discharge; electrostatic precipitator; submicrometer particles;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2005.851017