DocumentCode
1000828
Title
Gamma induced dose fluctuations in a charge injection device
Author
Burke, E.A. ; Bender, G.E. ; Pimbley, J.K. ; Summers, G.P. ; Dale, C.J. ; Xapsos, M.A. ; Marshall, P.W.
Author_Institution
Mission Res. Corp., San Diego, CA, USA
Volume
35
Issue
6
fYear
1988
fDate
12/1/1988 12:00:00 AM
Firstpage
1302
Lastpage
1306
Abstract
Spatial fluctuations in absorbed dose became important as device dimensions are scaled downward and the number of elements on a single chip increased. Furthermore, the extreme events in the distribution could determine the satisfactory operation of the array. The large sample size available in a charge injection device (CID) has made it possible, for the first time, to compare experimental results for gamma-induced dose fluctuations with theoretical calculations of extreme value distributions. The agreement between theory and experiment is excellent. In order to predict correctly the variance in the dose distribution from the basic model for solid-state imagers, it is found to be necessary in the case of a CID to include a term for carrier diffusion
Keywords
CCD image sensors; dosimetry; gamma-ray effects; CID; absorbed dose; carrier diffusion; charge injection device; dose distribution; extreme value distributions; gamma-induced dose fluctuations; solid-state imagers; Charge coupled devices; Fluctuations; Predictive models; Radiation effects; Semiconductor device measurement; Sensor arrays; Solid modeling; Solid state circuits; Statistical analysis; Ultraviolet sources;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.25456
Filename
25456
Link To Document