• DocumentCode
    1000842
  • Title

    Parylene surface-micromachined membranes for sensor applications

  • Author

    Fan, Zhifang ; Engel, Jonathan M. ; Chen, Jack ; Liu, Chang

  • Author_Institution
    Syst. Group, Univ. of Illinois, Urbana, IL, USA
  • Volume
    13
  • Issue
    3
  • fYear
    2004
  • fDate
    6/1/2004 12:00:00 AM
  • Firstpage
    484
  • Lastpage
    490
  • Abstract
    This paper reports the design, fabrication process, and testing results of Parylene surface-micromachined membranes with integrated strain gauges or thermal resistors made of thin film metals. The membrane is suspended above the substrate. This paper demonstrates the feasibility of sensor applications with a force (tactile) sensor and a fluid shear stress sensor.
  • Keywords
    force sensors; membranes; metallic thin films; micromachining; microsensors; polymer films; strain gauges; surface treatment; tactile sensors; thermal resistance; fluid shear stress sensor; force sensor; integrated strain gauges; parylene surface-micromachined membranes; sensor applications; thermal resistors; thin film metals; Biomembranes; Capacitive sensors; Fabrication; Process design; Resistors; Substrates; Tactile sensors; Testing; Thermal resistance; Transistors; Parylene; polymer; strain gauges; surface micromachining;
  • fLanguage
    English
  • Journal_Title
    Microelectromechanical Systems, Journal of
  • Publisher
    ieee
  • ISSN
    1057-7157
  • Type

    jour

  • DOI
    10.1109/JMEMS.2004.825295
  • Filename
    1303626