  • Title

    A New Method of Ground Fault Protection

  • Author

    Starr, F.M.

  • Author_Institution
    Gen. Elec. Co. Schenectady, N. Y.
  • Volume
    53
  • Issue
    11
  • fYear
    1934
  • Firstpage
    1472
  • Lastpage
    1477
  • Abstract
    A new high-resistance ``thyrite´´ and a new 3-element cold-cathode tube having unusual characteristics constitute the basic elements in a new high voltage relay combination for relaying or detecting ground faults on ungrounded systems. This scheme of protection, as described herein, is characterized by its reliability, simplicity, sensitivity, and low cost. It has been found to be particularly valuable in network applications.
  • Keywords
    Circuit faults; Electrical fault detection; Power system faults; Power system protection; Power system relaying; Power system reliability; Protective relaying; Resistors;