DocumentCode :
1003707
Title :
Irregular Windings in Wound Rotor Induction Motors
Author :
Hellmund, R. E. ; Veinott, C. G.
Author_Institution :
Westinghouse Elec. & Mfg. Co., E. Pittsburgh, Pa.
Volume :
53
Issue :
2
fYear :
1934
Firstpage :
342
Lastpage :
346
Abstract :
The importance of using regular windings in polyphase wound rotor induction motors is stressed in this paper. Harmful effects upon the efficiency, power factor, breakdown torque and noise of the motor may result with an irregular winding, due to differential leakage. The Goerges diagram of tooth fluxes is presented for studying this phenomenon. Means of avoiding trouble of this sort also are pointed out. It is further observed that 3-phase motors having a number of poles which is a multiple of 6 are most likely to be troublesome.
Keywords :
Coils; Electric breakdown; Induction motors; Power transformer insulation; Power transformers; Rotors; Surges;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1934.5056632
Filename :
5056632
Link To Document :
بازگشت