DocumentCode
1004366
Title
Design a Fuzzy Controller to Minimize the Effect of HVDC Commutation Failure on Power System
Author
Sun, Y.-Z. ; Peng, Ling ; Ma, Feng ; Li, G.J. ; Lv, P.F.
Author_Institution
Tsinghua Univ., Beijing
Volume
23
Issue
1
fYear
2008
Firstpage
100
Lastpage
107
Abstract
Commutation failure, which is a very frequent dynamic event in HVDC inverters, can deteriorate the availability of HVDC links and thus affect the performance of the power system. Most commutation failures are caused by voltage reduction due to ac system faults. In this paper, efforts are made to lower the effect of commutation failure on the power system, and the remedy is implemented in a fuzzy controller. In order to achieve control flexibility, the output of the fuzzy controller is made appropriate by setting a self-adjusting proportional factor. The validity and effectiveness of the fuzzy controller is verified by simulation which shows that the fuzzy controller can decrease commutation failure frequency induced by ac system faults.
Keywords
HVDC power convertors; HVDC power transmission; commutation; fuzzy control; power transmission control; power transmission faults; AC system faults; HVDC commutation failure; fuzzy controller; power transmission control; self-adjusting proportional factor; Control systems; Fuzzy control; Fuzzy systems; HVDC transmission; Inverters; Power system dynamics; Power system faults; Power system simulation; Power systems; Proportional control; Commutation failure; HVDC transmission; fuzzy control; power system;
fLanguage
English
Journal_Title
Power Systems, IEEE Transactions on
Publisher
ieee
ISSN
0885-8950
Type
jour
DOI
10.1109/TPWRS.2007.913212