DocumentCode
1005171
Title
Time and frequency domain analysis of fault-tolerant space vector PWM VSI-fed induction motor drive
Author
Klima, J.
Author_Institution
Dept. of Electr. Eng. & Autom., Prague, Czech Republic
Volume
152
Issue
4
fYear
2005
fDate
7/8/2005 12:00:00 AM
Firstpage
765
Lastpage
774
Abstract
The use of a new space-vector modulation strategy for a voltage source inverter supplying a fault tolerant induction motor drive is investigated. Such a system uses two distinct space-vector modulation strategies to switch from the healthy to the faulty operation. The proposed modulation strategy for the faulty operation has the same symmetry as in a classical B6 inverter. The purely analytical results both in the time and frequency domain are based on the Laplace transform of the voltage space vectors. There is an excellent agreement between the analytically calculated waveforms and the experimentally determined ones. Therefore, the proposed analytical model becomes a very useful method under unbalanced, as well as balanced, supply conditions.
Keywords
Laplace transforms; PWM invertors; fault tolerance; induction motor drives; time-frequency analysis; Laplace transform; VSI-fed induction motor drive; classical B6 inverter; distinct space-vector modulation strategies; fault-tolerant space vector PWM VSI; faulty operation; time-frequency domain analysis;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:20045099
Filename
1468691
Link To Document