• DocumentCode
    1005171
  • Title

    Time and frequency domain analysis of fault-tolerant space vector PWM VSI-fed induction motor drive

  • Author

    Klima, J.

  • Author_Institution
    Dept. of Electr. Eng. & Autom., Prague, Czech Republic
  • Volume
    152
  • Issue
    4
  • fYear
    2005
  • fDate
    7/8/2005 12:00:00 AM
  • Firstpage
    765
  • Lastpage
    774
  • Abstract
    The use of a new space-vector modulation strategy for a voltage source inverter supplying a fault tolerant induction motor drive is investigated. Such a system uses two distinct space-vector modulation strategies to switch from the healthy to the faulty operation. The proposed modulation strategy for the faulty operation has the same symmetry as in a classical B6 inverter. The purely analytical results both in the time and frequency domain are based on the Laplace transform of the voltage space vectors. There is an excellent agreement between the analytically calculated waveforms and the experimentally determined ones. Therefore, the proposed analytical model becomes a very useful method under unbalanced, as well as balanced, supply conditions.
  • Keywords
    Laplace transforms; PWM invertors; fault tolerance; induction motor drives; time-frequency analysis; Laplace transform; VSI-fed induction motor drive; classical B6 inverter; distinct space-vector modulation strategies; fault-tolerant space vector PWM VSI; faulty operation; time-frequency domain analysis;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa:20045099
  • Filename
    1468691