• DocumentCode
    1006195
  • Title

    Analysis of telemetric system based on remote resonant sensing circuit

  • Author

    de Oliveira, R.J.F. ; Abatti, P.J.

  • Author_Institution
    Parana Fed. Univ. of Technol., Curitiba, Brazil
  • Volume
    42
  • Issue
    13
  • fYear
    2006
  • fDate
    6/22/2006 12:00:00 AM
  • Firstpage
    750
  • Lastpage
    752
  • Abstract
    The resonance frequency (f0) of a remote resonant circuit can be determined by comparing its response under different excitation signal frequencies. It is demonstrated that a sudden modification of excitation signal frequency produces a transient response which may introduce errors of the f0 determination. Experimental results are presented.
  • Keywords
    electric sensing devices; telemetry; transient response; remote resonant sensing circuit; resonance frequency; telemetric system; transient response;