• DocumentCode
    1007602
  • Title

    Assessment of deterioration in epoxy/mica machine insulation

  • Author

    Kim, Y.J. ; Nelson, J.K.

  • Author_Institution
    Dept. of Electr. Power Eng., Rensselaer Polytech. Inst., Troy, NY, USA
  • Volume
    27
  • Issue
    5
  • fYear
    1992
  • Firstpage
    1026
  • Lastpage
    1039
  • Abstract
    Long-time accelerated aging tests in a laboratory environment have been conducted on generator stator insulation to identify meaningful diagnostic measures for the assessment of degradation and identification of aging mechanisms. A plurality of techniques are investigated and diagnostic parameter, the dynamic stagnation voltage, which appears to be correlated with delimination in the epoxy-mica structure, is proposed. The results provide a basis for an online interpretation method for insulation condition.<>
  • Keywords
    ageing; composite insulating materials; computerised monitoring; life testing; machine insulation; organic insulating materials; accelerated aging tests; aging mechanisms identification; degradation assessment; delimination; diagnostic measures; dynamic stagnation voltage; epoxy-mica structure; generator stator insulation; insulation condition; laboratory environment; long term testing; machine insulation; online interpretation method; plurality of techniques; Accelerated aging; Dielectric loss measurement; Dielectrics and electrical insulation; Electric variables measurement; Insulation testing; Laboratories; Pulse measurements; Stators; Thermal stresses; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.256478
  • Filename
    256478