DocumentCode :
1008273
Title :
A subcable test facility
Author :
Kim, S.H.
Author_Institution :
Argonne National Laboratory, Argonne, IL
Volume :
21
Issue :
2
fYear :
1985
fDate :
3/1/1985 12:00:00 AM
Firstpage :
406
Lastpage :
407
Abstract :
A subcable test facility was prepared to study ac losses and stabiilty of subsize cables under the pulsing magnetic field of a 40-kJ split-pair coil. A G-10 cryostat fabricated for the system has an inner diameter of 31 cm and is 170 cm deep. An 80-kW power supply for the coil has a pulsing mode of triangular operation. Another 500-kW power supply, rated for dc operation at 400 V and 1250 A, can have pulsing modes of triangular, trapezoidal, or ( B + \\dot{B} ) superimposed. AC losses of a superconducting composite strand with CuNi outer sheath were measured. Coupling losses among the strands were not significant because of the outer sheath.
Keywords :
Magnetic losses; Magnetic measurements; Power cable testing; Superconducting cables; Conductors; Helium; Loss measurement; Power supplies; Pulsed power supplies; Superconducting cables; Superconducting coils; Superconductivity; System testing; Test facilities;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1985.1063655