Title :
A prototype silicon preradiator for the SSC
Author :
Arodzero, Anatoli ; Brau, J. ; Frey, R. ; Furuno, K. ; Hwang, Han-jeong ; Mason, D. ; Strom, D. ; Yang, Xu ; Bashindzhagyan, G. ; Todd, R.A.
Author_Institution :
Dept. of Phys., Oregon Univ., Eugene, OR, USA
fDate :
8/1/1993 12:00:00 AM
Abstract :
The design and first results from the test of a prototype of a preradiator detector are described. Such a detector could be used to enhance the identification of photons and electrons at the Superconducting Super Collider (SSC). The authors´ prototype consists of a tungsten radiator followed by silicon strip detectors. The tungsten thickness is changeable, varying from 0 to 3 radiation lengths. Two silicon detectors, oriented in X and Y, consist of 48 strips, each with a length of 48 mm. The pitch is 1 mm. This granularity is required for separating single and multi-photons at the SSC. The readout is achieved by low-noise, low-power custom preamplifier chips mounted directly on the detectors via custom circuit boards. This preradiator was tested in a beam at Brookhaven National Laboratory. The results from the test on spatial distributions and energy resolution, including correction for the energy deposited in the preradiator, are presented
Keywords :
electron detection and measurement; gamma-ray detection and measurement; position sensitive particle detectors; semiconductor counters; 48 mm; SSC; Si preradiator; Superconducting Super Collider; W radiatior; electrons; energy resolution; photons; preamplifier chips; readout; Circuit testing; Detectors; Electrons; Photon collider; Preamplifiers; Printed circuits; Prototypes; Silicon; Strips; Tungsten;
Journal_Title :
Nuclear Science, IEEE Transactions on