DocumentCode
1009700
Title
Induction Motors Under Unblanced Conditions
Author
Lunn, Edward O.
Author_Institution
University of British Columbia, Vancouver; Peterson and Cowan Elevator Co. Ltd., Vancouver, B. C.
Volume
55
Issue
4
fYear
1936
fDate
4/1/1936 12:00:00 AM
Firstpage
387
Lastpage
393
Abstract
A general equation (17) for the output of an induction motor operating under unbalanced conditions of applied voltage and primary and secondary impedance, is deduced in terms of frequency of applied voltage, slip, and rotor copper losses, General equations for the currents flowing in the windings are given in appendix I, from which the secondary copper losses, and hence the output and torque, may be calculated. Special conditions of partial unbalance also are considered.
Keywords
Cable shielding; Circuit faults; Conductors; Impedance measurement; Induction motors; Power cables; Power measurement; Substations; Underground power cables;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1936.5057278
Filename
5057278
Link To Document