DocumentCode
1010117
Title
On-load test of the 20kVA superconducting generator
Author
Okada, T. ; Nitta, T. ; Shintani, T.
Author_Institution
Kyoto University, Yoshida-honmachi Sakyo-ku Kyoto, Japan
Volume
21
Issue
2
fYear
1985
fDate
3/1/1985 12:00:00 AM
Firstpage
668
Lastpage
671
Abstract
The on-load tests are carried out on an experimental power system, where the 20 kVA superconducting synchronous generator is connected to the regional power system through reactors (artificial transmission lines). The cooling characteristics of the rotor, especially, the cold damper, are obtained. On the on-load tests, active power vs. reactive power, active power vs. load angle, field current vs. active power characteristics at the constant terminal voltage, and so on are obtained. The transient behavior of the generator for a small variation of the input power is obtained. A transient analysis for the above test was carried out. Good agreement between the measured and calculated values is confirmed. From the results, the characteristics of superconducting generators are compared with those of the conventional ones and discussed.
Keywords
Rotating machine testing; Superconducting rotating machines; Synchronous generators; Cooling; Inductors; Power system transients; Power systems; Power transmission lines; Reactive power; Rotors; Superconducting transmission lines; Synchronous generators; System testing;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1985.1063807
Filename
1063807
Link To Document