DocumentCode
1011065
Title
Short-Time Spark-Over of Gaps
Author
Hagenguth, J.H.
Author_Institution
Electrical engineer with the General Electric Company, Pittsfield, Mass.
Volume
56
Issue
1
fYear
1937
Firstpage
67
Lastpage
76
Abstract
In this paper data are presented on spark-over values of rod gaps, insulators, bushings, sphere gaps, and solid insulation for a range of spark-over times of approximately from 0.2 to 4 microseconds. The problems of accurate measurement that are involved are also discussed, and a shielded resistance voltage divider is described.
Keywords
Capacitance; Electrical resistance measurement; Impulse testing; Insulation; Insulators; Laboratories; Lightning; Sparks;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1937.5057423
Filename
5057423
Link To Document