• DocumentCode
    1017212
  • Title

    The Accuracy of Watt-Hour Meters on Intermittent Loads

  • Author

    Faucett, M.A. ; Keener, C.A. ; Helm, M.S.

  • Author_Institution
    Assistant professor of electrical engineering, University of Illinois Urbana.
  • Volume
    59
  • Issue
    8
  • fYear
    1940
  • Firstpage
    460
  • Lastpage
    464
  • Abstract
    A watt-hour meter on intermittent loads of a particular character may have a registration error. The magnitude of error is a function of the meter design, the periodicity of the intermittent component of load, ratio of intermittent component to total load, character of intermittent component, power factor of load, and adjustment of the friction compensation. The registration characteristic of a meter on most types of intermittent load can be predicted from the acceleration and deceleration curves for the meter disk.
  • Keywords
    Acceleration; Angular velocity; Friction; Load flow control; Magnetic circuits; Reactive power; Torque control;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1940.5058163
  • Filename
    5058163