Title :
Improved device performance by multistep or carbon co-implants
Author :
Liefting, Reinoud ; Wijburg, Rutger C M ; Custer, Jonathan S. ; Wallinga, Hans ; Saris, Frans W.
Author_Institution :
MESA Res. Inst., Twente Univ., Enschede, Netherlands
fDate :
1/1/1994 12:00:00 AM
Abstract :
High-energy ion implantation is used for forming the collector in vertical bipolar transistors in a BiCMOS process. Secondary defects, remaining after annealing the implant damage, give rise to an increased leakage current and to collector-emitter shorts. These shorts reduce the transistor yield. The use of multiple step implants or the introduction of a C gettering layer are demonstrated to avoid dislocation formation. Experimental results show that these schemes subsequently lower the leakage current and dramatically increase device yield. The presence of C can cause increased collector/substrate leakage, indicating that the C profile needs to be optimized with respect to the doping profiles
Keywords :
BiCMOS integrated circuits; annealing; bipolar transistors; doping profiles; getters; ion implantation; leakage currents; BiCMOS process; C gettering layer; Si:B,C; coimplantation; collector formation; collector-emitter shorts; collector/substrate leakage; device performance; dislocation suppression; doping profiles; high-energy ion implantation; implant damage annealing; leakage current; multiple step implants; secondary defects; transistor yield; vertical bipolar transistors; Annealing; BiCMOS integrated circuits; Bipolar transistors; CMOS technology; Doping profiles; Gettering; Implants; Ion implantation; Leakage current; Physics;
Journal_Title :
Electron Devices, IEEE Transactions on