Abstract
The characteristics of partial arcs on contaminated surfaces are believed to dominate the withstand voltage of a contaminated insulator. The structure of a DC partial arc on an experimental model of an insulator surface contaminated with sodium chloride is investigated using a still camera and an interferometric method. The results reveal a difference in the structure of the positive and the negative partial arcs, and make it possible to explain the cause of the polarity effect in the withstand voltage of a heavily contaminated DC insulator, namely, the negative withstand voltage is lower than the positive. It is concluded that knowledge of the structure of partial arcs can be used in constructing an advanced mathematical model of the flashover phenomenon on a contaminated surface
Keywords
arcs (electric); flashover; insulators; DC insulator; DC withstand voltages; NaCl; contaminated insulator; contaminated surfaces; flashover phenomenon; interferometric method; negative withstand voltage; partial arcs; polarity effect; positive withstand voltage; still camera; Cameras; Character recognition; Dielectric liquids; Flashover; Insulation; Mathematical model; Surface contamination; Surface discharges; Switches; Voltage;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/14.16530
Filename
16530
Link To Document