• DocumentCode
    1019146
  • Title

    The ``Black Band´´ Method of Commutation Observation

  • Author

    Schroeder, T.W. ; Aydelott, John C.

  • Author_Institution
    Central station engineering department of the General Electric Company, Schenectady, N. Y.
  • Volume
    60
  • Issue
    6
  • fYear
    1941
  • fDate
    6/1/1941 12:00:00 AM
  • Firstpage
    446
  • Lastpage
    451
  • Abstract
    Good commutation is essential for the reliable performance of d-c machines with low maintenance costs. As an aid to the commutation adjustment of machines in the factory, or in the field, a systematic test procedure has been found useful on large machines to indicate certain features of the machine´s adjustment, notably the commutating field strength and brush position. This information is obtained directly from curves known as ``black bands´´ or ``buck and boost curves´´ plotted from test observations. The significance and interpretation of these curves in terms of machine adjustments, differential between commutation-reactance voltage and voltage induced by interpole flux are presented and results of observations on machines for special service (variable-speed motors and variable-voltage generators) are also given in this paper. Included are typically shaped ``black bands,´´ obtained in practice. The black-band method has proved to be an extremely powerful and useful tool in commutation adjustment and it is hoped that this discussion of it will lead to an increasing use of the method with a corresponding furtherance of knowledge about it, thus enlarging its scope of usefulness.
  • Keywords
    Bars; Brushes; Commutation; Costs; Maintenance; Petroleum; Production facilities; System testing; Vibrations; Voltage;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1941.5058359
  • Filename
    5058359