DocumentCode
1019758
Title
Corrosive Sulfur in Insulating Oils: Its Detection and Correlated Power Apparatus Failures
Author
Scatiggio, F. ; Tumiatti, V. ; Maina, R. ; Tumiatti, M. ; Pompili, M. ; Bartnikas, R.
Author_Institution
TERNA, Marghera
Volume
23
Issue
1
fYear
2008
Firstpage
508
Lastpage
509
Abstract
Contamination of paper tapes by corrosive sulfur in insulating oils may cause shorting faults between turns. Typically, this occurs at higher temperature in the upper portions of the windings of shunt reactors and power transformers. In many of the tested oils, high amounts of dibenzyl-disulfide (DBDS) were found.
Keywords
power transformer insulation; reactors (electric); sulphur; transformer oil; S; corrosive sulfur; dibenzyl-disulfide; insulating oils; paper tapes; power apparatus failures; power transformers; shunt reactors; Copper; Fault detection; Helium; Minerals; Ocean temperature; Oil insulation; Petroleum; Power transformer insulation; Strips; Testing; Oil insulation; standardization; transformers;