• DocumentCode
    1021011
  • Title

    Analytical Treatment for Establishing Load-Cycle Ratings of Ignitrons

  • Author

    Marshall, D.E. ; Arnott, E.G.F.

  • Author_Institution
    Section engineer, special products engineering department, Westinghouse Electric and Manufacturing Company, Bloomfield, N. J.
  • Volume
    61
  • Issue
    8
  • fYear
    1942
  • Firstpage
    545
  • Lastpage
    548
  • Abstract
    The above theory suggests a method of defining the intermittent rating of an ignitron tube through the use of a so-called time constant. This method results in a smooth transition from intermittent to continuous duty ratings. It is possible to adapt the time-constant concept to the calculation of permissible ratings for more complicated duty cycles than are considered in the present paper. The authors hope to be able, in the future, to check the actual performance of tubes against the above theory, especially at values approaching the continuous current rating.
  • Keywords
    Anodes; Capacity planning; Cathodes; Circuits; Electron emission; Resistance heating; Testing; Thermal stresses; Welding;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1942.5058560
  • Filename
    5058560