Analytical Treatment for Establishing Load-Cycle Ratings of Ignitrons
Author
Marshall, D.E. ; Arnott, E.G.F.
Author_Institution
Section engineer, special products engineering department, Westinghouse Electric and Manufacturing Company, Bloomfield, N. J.
Volume
61
Issue
8
fYear
1942
Firstpage
545
Lastpage
548
Abstract
The above theory suggests a method of defining the intermittent rating of an ignitron tube through the use of a so-called time constant. This method results in a smooth transition from intermittent to continuous duty ratings. It is possible to adapt the time-constant concept to the calculation of permissible ratings for more complicated duty cycles than are considered in the present paper. The authors hope to be able, in the future, to check the actual performance of tubes against the above theory, especially at values approaching the continuous current rating.
Keywords
Anodes; Capacity planning; Cathodes; Circuits; Electron emission; Resistance heating; Testing; Thermal stresses; Welding;