DocumentCode
1021715
Title
A New One-Cycle Directional Overcurrent Relay
Author
Morris, W.C.
Author_Institution
Design engineer, relay department, General Electric Company, Philadelphia, Pa.
Volume
62
Issue
11
fYear
1943
Firstpage
725
Lastpage
727
Abstract
This paper describes a new one-cycle directional overcurrent relay which is not limited in its application by lack of contact co-ordination. That contact coordination is important is indicated by the many incorrect relay operations which have been traced to the common practice of adding instantaneous attachment to directional overcurrent relays. For years it has been known that directional control is not sufficient for instantaneous directional over-current relays. This paper describes a new application of ``memory action´´ which for the first time complements directional control to give always correct operation. The new idea is to use ``memory action´´ to obtain a time delay in the operation of the overcurrent unit in the order of one-half cycle. Of course ``memory action´´ is also used in the directional element to retain a high torque level even if the fault causes drastic voltage reduction. Both elements are of the rugged induction cylinder.
Keywords
Circuit breakers; Circuit faults; Delay effects; Fault currents; Power system relaying; Power system stability; Protection; Protective relaying; Relays; Torque;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1943.5058637
Filename
5058637
Link To Document