Title :
Three-dimensional myocardial strain reconstruction from tagged MRI using a cylindrical B-spline model
Author :
Deng, Xiang ; Denney, Thomas S., Jr.
Author_Institution :
Dept. of Electr. & Comput. Eng., Auburn Univ., AL, USA
fDate :
7/1/2004 12:00:00 AM
Abstract :
In this paper, we present a new method for reconstructing three-dimensional (3-D) left ventricular myocardial strain from tagged magnetic resonance (MR) image data with a 3-D B-spline deformation model. The B-spline model is based on a cylindrical coordinate system that more closely fits the morphology of the myocardium than previously proposed Cartesian B-spline models and does not require explicit regularization. Our reconstruction method first fits a spatial coordinate B-spline displacement field to the tag line data. This displacement field maps each tag line point in the deformed myocardium back to its reference position (end-diastole). The spatial coordinate displacement field is then converted to material coordinates with another B-spline fit. Finally, strain is computed by analytically differentiating the material coordinate B-spline displacement field with respect to space. We tested our method with strains reconstructed from an analytically defined mathematical left ventricular deformation model and ten human imaging studies. Our results demonstrate that a quadratic cylindrical B-spline with a fixed number of control points can accurately fit a physiologically realistic range of deformations. The average 3-D reconstruction computation time is 20 seconds per time frame on a 450 MHz Sun Ultra80 workstation.
Keywords :
biomechanics; biomedical MRI; cardiology; deformation; image reconstruction; medical image processing; physiological models; splines (mathematics); 20 s; 3-D B-spline deformation model; 450 MHz; Sun Ultra workstation; end-diastole; left ventricle; magnetic resonance imaging; quadratic cylindrical B-spline model; spatial coordinate B-spline displacement field; tagged MRI; three-dimensional myocardial strain reconstruction; Capacitive sensors; Deformable models; Image reconstruction; Magnetic field induced strain; Magnetic resonance; Magnetic resonance imaging; Morphology; Myocardium; Reconstruction algorithms; Spline; Algorithms; Heart Ventricles; Humans; Image Enhancement; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Magnetic Resonance Imaging; Models, Cardiovascular; Models, Statistical; Myocardium;
Journal_Title :
Medical Imaging, IEEE Transactions on
DOI :
10.1109/TMI.2004.827961