• DocumentCode
    1027919
  • Title

    Locked-Rotor Temperature Test Repeatability-Small Impedance-Protected Motor

  • Author

    Chi, J.N.C.

  • Author_Institution
    General Electric Company
  • Volume
    82
  • Issue
    68
  • fYear
    1963
  • Firstpage
    601
  • Lastpage
    608
  • Abstract
    Locked-rotor motor-temperature tests can be highly repeatable when the test conditions consist of ambient temperature, proximity draft, mounting geometry etc., and are held identical. Since any change of these conditions will affect the motor temperature, the latter can be meaningful only when the former are precisely defined. In judging motor temperature with reference to a temperature limit specified under a different set of conditions, allowance is to be made to account for the difference of conditions.
  • Keywords
    Equations; Heat transfer; Impedance; Manufacturing; Mercury (metals); Ocean temperature; Sea level; Sea measurements; Temperature measurement; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1963.291374
  • Filename
    4072844