Title :
An Experimental Study of Cooling Flow Distribution in a Model Alternator
Author :
Munton, R.J. ; Markland, E.
Author_Institution :
University of Nottingham
Abstract :
One-fourth-scale model tests on three arrangements of the cooling flow system of a 30-mw (megawatt) alternator have revealed wide variations in the flow distribution, both in longitudinal and circumferential directions. A 5-compartment stator was found to be more satisfactory than a 3-compartment or singlecompartment arrangement, with regard to both total flow quantity and evenness of distribution. A fair approximation to the longitudinal distribution was obtained by neglecting friction losses, other than in the stator.
Keywords :
Alternators; Coolants; Cooling; Friction; Machinery; Mechanical engineering; Stators; System testing; Temperature; Ventilation;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1963.291471