• DocumentCode
    1028294
  • Title

    An Experimental Study of Cooling Flow Distribution in a Model Alternator

  • Author

    Munton, R.J. ; Markland, E.

  • Author_Institution
    University of Nottingham
  • Volume
    82
  • Issue
    69
  • fYear
    1963
  • Firstpage
    896
  • Lastpage
    900
  • Abstract
    One-fourth-scale model tests on three arrangements of the cooling flow system of a 30-mw (megawatt) alternator have revealed wide variations in the flow distribution, both in longitudinal and circumferential directions. A 5-compartment stator was found to be more satisfactory than a 3-compartment or singlecompartment arrangement, with regard to both total flow quantity and evenness of distribution. A fair approximation to the longitudinal distribution was obtained by neglecting friction losses, other than in the stator.
  • Keywords
    Alternators; Coolants; Cooling; Friction; Machinery; Mechanical engineering; Stators; System testing; Temperature; Ventilation;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1963.291471
  • Filename
    4072885