An Experimental Study of Cooling Flow Distribution in a Model Alternator
Author
Munton, R.J. ; Markland, E.
Author_Institution
University of Nottingham
Volume
82
Issue
69
fYear
1963
Firstpage
896
Lastpage
900
Abstract
One-fourth-scale model tests on three arrangements of the cooling flow system of a 30-mw (megawatt) alternator have revealed wide variations in the flow distribution, both in longitudinal and circumferential directions. A 5-compartment stator was found to be more satisfactory than a 3-compartment or singlecompartment arrangement, with regard to both total flow quantity and evenness of distribution. A fair approximation to the longitudinal distribution was obtained by neglecting friction losses, other than in the stator.
Keywords
Alternators; Coolants; Cooling; Friction; Machinery; Mechanical engineering; Stators; System testing; Temperature; Ventilation;