DocumentCode
1028753
Title
Transient flux requirement of a matching transformer in a series resonant inverter
Author
Jain, Praveen ; Dewan, S.B.
Author_Institution
University of Toronto, Toronto, Canada
Volume
23
Issue
5
fYear
1987
fDate
9/1/1987 12:00:00 AM
Firstpage
2782
Lastpage
2784
Abstract
This paper determines the transient flux level of a matching transformer in a series resonant inverter. At starting, the transformer will saturate if it is not designed corresponding to the transient flux level. The saturation of the transformer will short circuit the output of the inverter and will result in the failure of inverter operation. A transient analysis of the inverter is, therefore, presented to obtain the transient flux level of the transformer. All the theoretical results obtained have been verified experimentally.
Keywords
DC-AC power conversion; Impedance-matching; Industrial power system transients; Power conversion, DC-AC; Circuit faults; Diodes; Induction generators; Reactive power; Resonance; Resonant frequency; Resonant inverters; Switches; Transient analysis; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.1987.1065432
Filename
1065432