DocumentCode
1028947
Title
An accurate technique for measuring the on-axis axial ratio of circularly polarized feed systems
Author
Greene, Kieran J. ; Thomas, Bruce Maca
Author_Institution
Commonwealth Scientific and Industrial Research Organization, Epping, NSW, Australia
Volume
32
Issue
12
fYear
1984
fDate
12/1/1984 12:00:00 AM
Firstpage
1379
Lastpage
1382
Abstract
A method for swept-frequency measurement of the on-axis axial ratio of circularly polarized feed systems is described. The method is suitable for measuring the resultant axial ratio of a feed plus horn assembly. The performance of the feed (diplexer) alone may also be measured by using a simple terminating horn designed for very low reflection coefficient. A comparison with established techniques shows advantages for the new method, either in simplicity or accuracy. The precautions necessary to achieve the high degree of accuracy obtainable are also considered.
Keywords
Antenna measurements; Reflector antenna feeds; Anechoic chambers; Assembly; Feeds; Magnetic field measurement; Polarization; Probes; Reflection; Rotation measurement; Satellite ground stations; Transducers;
fLanguage
English
Journal_Title
Antennas and Propagation, IEEE Transactions on
Publisher
ieee
ISSN
0018-926X
Type
jour
DOI
10.1109/TAP.1984.1143263