• DocumentCode
    1028947
  • Title

    An accurate technique for measuring the on-axis axial ratio of circularly polarized feed systems

  • Author

    Greene, Kieran J. ; Thomas, Bruce Maca

  • Author_Institution
    Commonwealth Scientific and Industrial Research Organization, Epping, NSW, Australia
  • Volume
    32
  • Issue
    12
  • fYear
    1984
  • fDate
    12/1/1984 12:00:00 AM
  • Firstpage
    1379
  • Lastpage
    1382
  • Abstract
    A method for swept-frequency measurement of the on-axis axial ratio of circularly polarized feed systems is described. The method is suitable for measuring the resultant axial ratio of a feed plus horn assembly. The performance of the feed (diplexer) alone may also be measured by using a simple terminating horn designed for very low reflection coefficient. A comparison with established techniques shows advantages for the new method, either in simplicity or accuracy. The precautions necessary to achieve the high degree of accuracy obtainable are also considered.
  • Keywords
    Antenna measurements; Reflector antenna feeds; Anechoic chambers; Assembly; Feeds; Magnetic field measurement; Polarization; Probes; Reflection; Rotation measurement; Satellite ground stations; Transducers;
  • fLanguage
    English
  • Journal_Title
    Antennas and Propagation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-926X
  • Type

    jour

  • DOI
    10.1109/TAP.1984.1143263
  • Filename
    1143263