• DocumentCode
    1029028
  • Title

    Measurement of High Q Cavities at 10,000 Megacycles

  • Author

    Lange, R.W.

  • Author_Institution
    Bell Telephone Laboratories, Inc., New York, N. Y.
  • Volume
    66
  • Issue
    1
  • fYear
    1947
  • Firstpage
    161
  • Lastpage
    166
  • Abstract
    Known methods of measuring Q in high Q resonant cavities, together with their accuracies and sources of error are discussed. For relatively low values of Q and of frequency, it is shown that band width methods are more accurate than decrement methods. For values of Q above 30,000 at frequencies above 3,000 megacycles the reverse is true. The significant feature of the present method, the wide range heterodyne decrement method, is that the accuracy is improved by observing the decay over a relatively long interval of time. An absolute accuracy of plus or minus three per cent and a relative accuracy of plus or minus two per cent are achieved. Design features and performance are discussed and constructional details are presented.
  • Keywords
    Coupling circuits; Current measurement; Electric variables measurement; Equations; Frequency measurement; Impedance measurement; Oscillators; Propagation losses; Q measurement; Resonance;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1947.5059420
  • Filename
    5059420