DocumentCode :
1029462
Title :
A nonrotating multiparameter 3-D X-ray imaging system-Part II: design and experiments
Author :
Jama, Hassan A. ; Hussein, Esam M A ; Khettabi, F.E.
Author_Institution :
Dept. of Mech. Eng., Univ. of New Brunswick, Fredericton, NB, Canada
Volume :
51
Issue :
3
fYear :
2004
fDate :
6/1/2004 12:00:00 AM
Firstpage :
648
Lastpage :
658
Abstract :
The design aspects of a 3-D X-ray imaging system that eliminates the rotation process associated with tomographic systems are discussed. The processes of selecting the proper X-ray voltage and the beam configuration are addressed. A rectilinear scanning mechanism is introduced. The choice and design of detector assemblies are described. The paper presents the results of experiments devised to progressively test the performance and response of the system.
Keywords :
Compton effect; X-ray imaging; particle detectors; radioactive sources; Compton scattering; X-ray sources; X-ray voltage; beam configuration; design aspect; detector assemblies; nonrotating multiparameter 3-D X-ray imaging system; rectilinear scanning mechanism; rotation process; tomographic system; Collimators; Electromagnetic scattering; Energy measurement; Object detection; Particle scattering; Tomography; X-ray detection; X-ray detectors; X-ray imaging; X-ray scattering; -D imaging; Compton scattering; X-ray imaging;