Title
Laboratory Evaluation of 345-kY Cable 1 High-Pressure Polybutene Oil Pipe-Type Cable After Field Testing at Cornell University
Author
Goooding, F.H. ; Beer, R.R.
Author_Institution
The Okonite Company
Issue
4
fYear
1966
fDate
4/1/1966 12:00:00 AM
Firstpage
326
Lastpage
329
Abstract
After 3.6 years of overvoltage and high-temperature cycles at the Cornell University High-Voltage Testing Facility,1 sections of a prototype 345-kV 500-MVA cable and joints were returned for evaluation. Dielectric strength and loss were measured on the completed cable. Oil and paper properties were compared with similar tests made prior to the field testing.
Keywords
Dielectric breakdown; Dielectric loss measurement; Dielectric measurements; Laboratories; Loss measurement; Oil filled cables; Petroleum; Prototypes; Testing; Voltage control;