Title :
Laboratory Evaluation of 345-kY Pothead "C" After Field Testing at Cornell University
Author :
Lusk, G.E. ; Nicholas, J.H. ; Welter, C.L.
Author_Institution :
G & W Electric Specialty Company
fDate :
4/1/1966 12:00:00 AM
Abstract :
Three G & W potheads successfully withstood 3¿years of testing at Cornell with no evidence of electrical, mechanical, or thermal instability. Installation experience indicated that some features were susceptible to damage during installation. These features have been eliminated or suitably revised to prevent such problems in commercial installations.
Keywords :
Aluminum; Cable insulation; Capacitors; Degradation; Dielectrics; Laboratories; Petroleum; Stress control; Strips; Testing;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1966.291569