• DocumentCode
    1029694
  • Title

    The Development and Field Experience of a Transistor Electric Governor for Hydro Turbines

  • Author

    Leum, M.

  • Author_Institution
    Woodward Governor Co.
  • Issue
    4
  • fYear
    1966
  • fDate
    4/1/1966 12:00:00 AM
  • Firstpage
    393
  • Lastpage
    402
  • Abstract
    The general design requirement for an electric-hydraulic governing system for hydraulic turbines is that it must sense speed electrically, produce a signal suitable for control, and use this signal to position the gate servomotors. It must be capable of performing all auxiliary functions previously required plus some desirable new ones, such as joint control. The dead band must be less than 0.01 percent and the dead time less than 0.25 second. Its selling price should be equal to, or less than, mechanical governors. Its transient response characteristics must be excellent. The paper discusses how some of these goals have been met and presents results from field and shop tests.
  • Keywords
    Control systems; Diesel engines; Hydraulic turbines; Servomotors; Shafts; Signal design; Signal generators; Testing; Transducers; Transient response;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1966.291577
  • Filename
    4073048